TXT
묘사:
Dial Indicating Pressure Gage
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Rs charging panel; visual landing aids-braso code vla
MRC:
The increment of measure represented by the marking/s/ on the item.ANBJ
Graduation Unit:
100.0 pounds per square inch
MRC:
Indicates the type of actuation provided.APCM
Actuation Type:
Bourdon tube
MRC:
An indication of whether or not the item is adjustable.APCS
Adjustability:
Adjustable
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+500.0 pounds per square inch
MRC:
The nomenclature by which the scale is identified.AQFZ
Scale Name:
Pounds pressure
MRC:
Designates the size of the relative or proportionate dimensions of the dial.ARCH
Dial Size:
4.50in
MRC:
The number of connections furnished.ASMM
Connection Quantity:
1
MRC:
The hue or tint of the pointer.ASSS
Pointer Color:
Any acceptable
MRC:
Indicates the type of pointer provided.ASST
Pointer Type:
Indicating
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Dial
MRC:
The smallest value between the markings on a scale.AWAG
Scale Smallest Increment:
2.0 pounds per square inch
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
External
MRC:
The element,compound,or mixture of which an actuating element is fabricated,excluding any surface treatment.BGKY
Actuating Element Material:
Steel, stainless
MRC:
Indicates the connection location.BGRY
Connection Location:
Bottom
MRC:
Designates the size of the connection provided.BHMG
Connection Size:
0.25in npt male
MRC:
An indication of whether or not a connector type vent is provided.BHMK
Connector Type Vent:
Not provided
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Agav
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Operating temperature: -54 to 88degrees celsius