부품 정보
Pressure gage servicing, stored energy systems
TXT
묘사:
Dial Indicating Pressure Gage
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
2.500 inches
MRC:
The length of a straight line which passes through the center of a bolt circle,and terminates at the circumference.ABKG
Bolt Circle Diameter:
7.000 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.280 inches
MRC:
The number of mounting holes provided.ABTJ
Mounting Hole Quantity:
3
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
7.630 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
F-22 aircraft
MRC:
Indicates the type of actuation provided.APCM
Actuation Type:
Single coil helical bourdon tube
MRC:
An indication of whether or not the item is adjustable.APCS
Adjustability:
Adjustable
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+6000.0 pounds per square inch
MRC:
The nomenclature by which the scale is identified.AQFZ
Scale Name:
Pounds pressure
MRC:
Designates the size of the relative or proportionate dimensions of the dial.ARCH
Dial Size:
6 inch diameter
MRC:
The number of connections furnished.ASMM
Connection Quantity:
1
MRC:
Indicates the type of pointer provided.ASST
Pointer Type:
Reference
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Concentric dial
MRC:
The smallest value between the markings on a scale.AWAG
Scale Smallest Increment:
20.0 pounds per square inch
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
External
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flush flange
MRC:
The degree of conformity of a scale measurement to a standard or a true value.BGKS
Scale Accuracy:
0.25 pct full scale
MRC:
The element,compound,or mixture of which an actuating element is fabricated,excluding any surface treatment.BGKY
Actuating Element Material:
Iron constantan
MRC:
Indicates the scale name for which the pointer is designed.BGLC
Scale Name For Which Pointer Is Designed:
High pressure
MRC:
Indicates the connection location.BGRY
Connection Location:
Bottom
MRC:
Designates the size of the connection provided.BHMG
Connection Size:
0.250 in npt
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Dwg5vg90725
MRC:
Indicates the relationship,such as construction,capabilities,and the like,of the item to a similar item.RTSE
Relationship To Similar Equipment:
Replaced by 5vg90725-103 per dwg
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81205-5vg90725 manufacturers specification control