MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular, bracketed
MRC:
A measurement of the longest dimension of the slot,in distinction from width.ABGD
Slot Length:
0.250 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.500 inches
Flat Height:
0.216 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.250 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.500 inches
Flatted Portion Length:
0.250 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Not rated
MRC:
The number of fixed or adjustable facilities provided to adjust an item.ACZT
Adjustment Device Quantity:
2
MRC:
Indicates the type of drive provided for the adjustment device.ACZU
Adjustment Device Drive Type:
Shaft
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.500 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
2.250 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
Shaft Style:
Round, flatted
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
1
MRC:
The longest distance between mounting centers parallel to the horizontal plane.AFDS
Longest Horizontal Distance Between Mounting Centers:
1.750 inches
MRC:
The longest distance between mounting centers parallel to the vertical plane.AFDV
Longest Vertical Distance Between Mounting Centers:
4.000 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-0.0/+70.0 degrees celsius
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Not rated
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Aluminum body
MRC:
The plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the item and its location.ANNR
Surface Treatment And Location:
Enamel, gray body
MRC:
The total oppositon (resistive and reactive) which the item offers to the input flow of alternating current.ANSL
Input Impedance Rating:
100.000 ohms
MRC:
The total opposition (resistive and reactive) which the item offers to the output flow of alternating current.ANSR
Output Impedance Rating:
100.000 ohms
MRC:
The differences between limiting frequencies of a frequency band.APQL
Frequency Bandwidth:
Not rated
MRC:
A measurement between specified points on a body in distinction from height.ARBR
Body Depth:
Any acceptable
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Slotted hole
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the mounting provision(s).BBBW
Mounting Provision Arrangement Style:
Four position rectangular
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
3.500
MRC:
The means by which the signal is delayed.BZWM
Signal Delay Method:
Lumped constant
MRC:
The means used to vary the delay time of the item.CCDN
Delay Time Variation Method:
Variable
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
6.400 microseconds single section
MRC:
The change in delay as a result of the temperature change per degree celsius.CCDT
Delay Time Variation Per Deg Celsius:
Not rated
MRC:
The rated time required for the pulse to rise.CCDX
Pulse Rise Time Rating:
250.0 nanoseconds
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
2 coaxial receptacle and 2 wire hook
MRC:
An overall measurement taken at right angles to the length of the slotted hole, in distinction from thickness.CDQK
Err Default:
Err default