TXT
묘사:
Electrical Power Cable Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
94.500 feet
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.928 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
4
MRC:
The specification, standard, drawing, or similar instrument that specifies the individual color coding under which the item is identified by an alphabetic and/or numeric reference number.includes the commercial and government entity (cage) code of the entity controlling the instrument.AWXS
Color Coding Document:
25-32849-81205 drawing
MRC:
The specification, standard, drawing, or similar instrument that specifies the individual color coding under which the item is identified by an alphabetic and/or numeric reference number.includes the commercial and government entity (cage) code of the entity controlling the instrument.AWXS
Color Coding Document:
25-32849-81205 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
133 2nd conductor
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
133 1st conductor
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
19 3rd conductor
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
19 4th conductor
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
2 twisted pair
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
First conductor first group and second conductor first group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Third conductor second group and fourth conductor second group
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
3000.0 dielectric test voltage all conductors
MRC:
Designates the size of the mounting aperture provided in the terminal lug.CXFM
Terminal Lug Aperture Size:
0.190 inches 2nd end first conductor
MRC:
Designates the size of the mounting aperture provided in the terminal lug.CXFM
Terminal Lug Aperture Size:
0.190 inches 2nd end second conductor
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor all conductors
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
External angle connector and lug
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Guided missile launching control groups