부품 정보
1 scale in h2, psi, brass center ba k connection, zink plated steel panel mount clamp, asme grade a accuracy working pressure limitations: dynamic pressure limited 60% dial range static pressure, where no sharp fluctuation occur, limited 90% dial range, ambient temp 0/140 ded f, measured media should not exceed 140 degrees f, over pressure protection and recalibrator available as options
TXT
묘사:
Dial Indicating Pressure Gage
MRC:
The number of mounting holes provided.ABTJ
Mounting Hole Quantity:
1
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
2.500 inches
MRC:
The increment of measure represented by the marking/s/ on the item.ANBJ
Graduation Unit:
1.0 pounds per square inch
MRC:
Indicates the type of actuation provided.APCM
Actuation Type:
Diaphragm
MRC:
An indication of whether or not the item is adjustable.APCS
Adjustability:
Nonadjustable
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+10.0 pounds pressure per square inch
MRC:
The nomenclature by which the scale is identified.AQFZ
Scale Name:
Pounds pressure
MRC:
Designates the size of the relative or proportionate dimensions of the dial.ARCH
Dial Size:
2.5 in diameter
MRC:
The number of connections furnished.ASMM
Connection Quantity:
1
MRC:
The hue or tint of the pointer.ASSS
Pointer Color:
Black
MRC:
Indicates the type of pointer provided.ASST
Pointer Type:
Indicating
MRC:
An indication of the marking(s) on the scale.ASTW
Scale Marking:
Amark per tenth pound, numbered mark every lb
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Dial
MRC:
The smallest value between the markings on a scale.AWAG
Scale Smallest Increment:
1.0 pounds per square inch
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
External
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
External
MRC:
The means of attaching the item.AXGY
Mounting Method:
Screw
MRC:
The degree of conformity of a scale measurement to a standard or a true value.BGKS
Scale Accuracy:
Plus or minus 1.5 % full scale
MRC:
The element,compound,or mixture of which an actuating element is fabricated,excluding any surface treatment.BGKY
Actuating Element Material:
Phosphor bronze
MRC:
The hue or tint of the inscription(s) and/or that portion of the scale which surrounds the inscription on the scale.BGKZ
Scale Inscription/background Color:
Black figures, white background
MRC:
Indicates the scale name for which the pointer is designed.BGLC
Scale Name For Which Pointer Is Designed:
Pounds pressure
MRC:
Indicates the connection location.BGRY
Connection Location:
Back, center
MRC:
The element,compound,or mixture of which the protective crystal is fabricated,excluding any surface treatment.BHMF
Protective Crystal Material:
Plastic, methyl-methacrylate
MRC:
Designates the size of the connection provided.BHMG
Connection Size:
0.250in npt
MRC:
Indicates the mounting connection location.BHMH
Mounting Connection Location:
Back, center
MRC:
An indication of whether or not a connector type vent is provided.BHMK
Connector Type Vent:
Not provided
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Low pressure diaphram test gauge
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Plastic, acrylonitrile-butadiene-styrene
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic acrylonitrile-butadiene-styrene (abs)