MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						2.312 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						1.438 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						0.859 inches 					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-40.0/+85.0 degrees celsius					
				 
							
					
						MRC:
						The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
					 
					
						Reference Frequency Per Function:
					
					
						8.75 megahertz blank					
				 
							
					
						MRC:
						The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).AHAU
					 
					
						Input Impedance Per Function W/load:
					
					
						50.0 ohms blank					
				 
							
					
						MRC:
						The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).AHAV
					 
					
						Output Impedance Per Function W/source Across Input:
					
					
						50.0 ohms blank					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance-resistance blank					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
					 
					
						Insertion Loss At Reference Frequency Per Function In Decibels:
					
					
						3.0 blank					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						1 wire hook input 1st function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						2 wire hook output 2nd function					
				 
							
					
						MRC:
						The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
					 
					
						Specified Frequencies Of Discrimination Per Function:
					
					
						7.95 megahertz blank and 8.50 megahertz blank and 9.00 megahertz blank and 9.55 megahertz blank					
				 
							
					
						MRC:
						The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
					 
					
						Frequency Band Width Per Function:
					
					
						8.50 megahertz blank and 9.00 megahertz blank					
				 
							
					
						MRC:
						The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
					 
					
						Discrimination At Specificationified Frequencies Per Function In Decibels:
					
					
						20.0  blank and 3.0  blank and 3.0  blank and 20.0  blank					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Rectangular terminal/terminals on one surface