MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.570 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.300 inches
MRC:
The measurement of the distance that the actuator protrudes from the body.AFGK
Actuator Length:
0.150 inches
Actuator Height:
0.200 inches
MRC:
A measurement taken at right angles to the length of the actuator,in distinction from thickness.AFUT
Actuator Width:
0.150 inches
MRC:
The relationship between the actuator position and the actuator action /maintained or momentary/.AFUX
Actuator Position-action Relationship:
Left position maintained and right position maintained
MRC:
The hue or tint of the actuator.AFVA
Actuator Color:
Black single actuator
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
120.0 ac
MRC:
The means of attaching the item.AXGY
Mounting Method:
Integral
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
2 pole, double throw, both positions maintained single switch unit
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
0.500 amperes resistive ac
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 printed circuit