TXT
				
				
					묘사:
				
				
					Rotary Switch Section				
			 
			
										
					
						MRC:
						A measurement of the longest straight line across a circular cross-sectional plane.ADAV
					 
					
						Overall Diameter:
					
					
						2.000 inches 					
				 
							
					
						MRC:
						A measurement of the smallest dimension of a body,in distinction from length or width.ADPR
					 
					
						Body Thickness:
					
					
						0.062 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.130 inches  single mounting facility					
				 
							
					
						MRC:
						The longest distance between mounting centers parallel to the horizontal plane.AFDS
					 
					
						Longest Horizontal Distance Between Mounting Centers:
					
					
						1.562 inches  single mounting facility					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-65.0 to 100.0 degrees celsius					
				 
							
					
						MRC:
						The general configuration of the contacts of a switch that describes its basic switching structure.AJZE
					 
					
						Switch Contact Basic Design:
					
					
						Nonpile-up nonsymmetrical					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Strut single mounting facility					
				 
							
					
						MRC:
						The voltage for which the contacts are rated,expressed in volts.CQMK
					 
					
						Contact Voltage Rating In Volts:
					
					
						110.0 ac at sea level					
				 
							
					
						MRC:
						The voltage for which the contacts are rated,expressed in volts.CQMK
					 
					
						Contact Voltage Rating In Volts:
					
					
						28.0 dc at sea level					
				 
							
					
						MRC:
						Indicates the type of terminal for providing electrical connection to the item.CSCF
					 
					
						Terminal Type:
					
					
						Tab,  solder lug					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						2.0 amperes resistive load dc at sea level					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						1.0 amperes resistive load ac at sea level					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Switch section,  rotary					
				 
							
					
						MRC:
						The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
					 
					
						Test Data Document:
					
					
						81349-mil-s-3786 specification (includes engineering type bulletins,  brochures, etc.,  that reflect specification type data in specification format;  excludes commercial catalogs,  industry directories,  and similar trade publications,  reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical",  "average",  "",  etc.).