MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 4.344 inches and 4.719 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 2.500 inches and 2.625 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 2.937 inches and 3.062 inches
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
10000.0 feet
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
105.0 ac volts single operating power rqmt and 125.0 ac volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
15.0 dc volts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-15.0 dc volts 2nd power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
400.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+55.0 degrees celsius
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 1st power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 2nd power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 2nd power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 1st power output
MRC:
The means used to change alternating current voltage to direct current voltage.BHQN
Rectification Method:
Single phase full wave center tap
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Filter
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
125.0 dc milliamperes 1st power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
-125.0 dc milliamperes 2nd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 2nd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 1st power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Solder lug 1st power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Solder lug 2nd power output