TXT
묘사:
Radio Frequency Interfere Filter
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.970 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.970 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
1.970 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
3.500 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-65.0/+85.0 degrees celsius
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-65.0 to 85.0 degrees celsius
MRC:
The cycles per second /hertz/ of the power line alternating current.AHBB
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
MRC:
The cycles per second /hertz/ of the power line alternating current.AHBB
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
MRC:
The cycles per second /hertz/ of the power line alternating current.AHBB
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
MRC:
The cycles per second /hertz/ of the power line alternating current.AHBB
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference 1st function
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
7.0 3rd radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
7.0 1st radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
7.0 2nd radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
10.0 5th radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
3.0 4th radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
10.0 5th radio interference 5th function
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
7.0 3rd radio interference 3rd function
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
7.0 1st radio interference 1st function
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference 5th function
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference 3rd function
MRC:
The identifying numeric code of the originator that controls or manufactures the input terminal.AHBN
Input Terminal Manufacturer Code:
96906
MRC:
The specification,standard,or manufacturers identification number or symbol used to identify the input terminal.AHBP
Input Terminal Identification:
Ms27503e-18b-11p
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
Mounting Facility Screw Thread Series Designator:
Unc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 threaded hole
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 threaded hole 2nd function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 connector, receptacle input 1st function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
3 tab, solder lug ground 3rd function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
5 tab, solder lug output 2nd function
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.138 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular terminal/terminals on one surface