TXT
묘사:
Electronic Circuit Plug Test Set
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 103.0 volts and 254.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Logic test unit; crt; keyboard
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Multiple item w/housing
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Go/no-go; fault isolation
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used to test printed circuit board assemblies
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Dim. Logic test unit 30.5 in.H, 20.0 in. W, 36.0 in. L, 198 lbs; crt 14.0 in. H, 17.0 in. W, 12.0 in. L, 33 lbs; keyboard 4.0 in. H, 17.0 in. W, 11.0 in. L, 15 lbs