부품 정보
Oscilloscope dc-100mhz: an/usm-488
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac and dc
MRC:
The number of beams provided on the item.ATES
Beam Quantity:
2
MRC:
The interval/s/ as indicated by the markings on the item.AWEC
Graduation Interval:
Graduated in volts per centimeterboth axis
MRC:
The acceptable limits of deviation from the designed standard output value of the item,expressed in percent.BDJD
Accuracy Range In Percent:
-5.0/+5.0
MRC:
An indication of whether or not sweep circuits are included.BGQL
Sweep Circuits:
Included
MRC:
An indication of whether or not a generator driven feature is included.BGQM
Generator Driven Feature:
Not included
MRC:
Indicates the type of sweep circuits provided.BGQN
Sweep Circuit Type:
Horizontal and vertical
MRC:
The range of complete cyclic changes,per unit of time,for which the sweep is rated.BGQP
Sweep Frequency Range:
+0.0/+100.0 megahertz
MRC:
The length of time consumed by a single trigger sweep.BGQQ
Single Trigger Sweep Duration:
Between 50.0 nanoseconds and 5.0 seconds
MRC:
The maximum absolute value for which the trigger sweep voltage is rated.BGRZ
Trigger Sweep Voltage Amplitude Rating:
Between 0.6 millivolts and 400.0 volts
MRC:
An indication of whether or not a trigger sweep polarity switch is included.BGSB
Trigger Sweep Polarity Switch:
Included
MRC:
The distance between indicated pulse intervals shown on the screen of a trigger sweep designed item.BGSC
Trigger Sweep Marker Intervals:
5 nanoseconds and 0.5 microseconds
MRC:
An indication of whether or not an expanded sweep is provided.BGSD
Expanded Sweep:
Provided
MRC:
An indication of whether or not provisions for rating the deflection sensitivity through the amplifier are provided.BHDD
Amplifier Deflection Sensitivity Provision:
Provided
MRC:
The value,or range of values,for which the vertical deflection sensitivity is rated.BHDF
Vertical Deflection Sensitivity Voltage Rating:
2.0 millivolts peak to peak per centimeter
MRC:
The value,or range of values,for which the horizontal deflection sensitivity is rated.BHDG
Horizontal Deflection Sensitivity Voltage Rating:
2.0 millivolts any acceptable megahertz
MRC:
An indication of whether or not an input intensity modulation feature is provided.BHDH
Input Intensity Modulation Feature:
Provided
MRC:
An indication of whether or not provisions for rating the direct connection to the plate deflection sensitivity is provided.BHDL
Plate Direct Connection Deflection Sensitivity Provision:
Not provided
MRC:
An indication of whether or not a frequency response rating is provided.BHDP
Frequency Response Rating:
Provided
MRC:
The minimum and maximum frequencies to which the x-axis will respond.BHDQ
X-axis Frequency Response Rating:
Between 0.0 megahertz and 2.5 megahertz
MRC:
The minimum and maximum frequencies to which the y-axis will respond.BHDR
Y-axis Frequency Response Rating:
Between 0.0 megahertz and 100.0 megahertz
MRC:
The minimum and maximum frequencies to which the z-axis will respond.BHDS
Z-axis Frequency Response Rating:
Between 0.0 megahertz and 20.0 megahertz
MRC:
An indication of whether or not amplifier input impedance rating is provided.BHDT
Amplifier Input Impedance Rating Provision:
Provided
MRC:
The total opposition (resistive and reactive) which the item offers to the x-axis input flow of alternating current.BHDW
X-axis Input Impedance Rating:
1.0 megohms
MRC:
The total opposition (resistive and reactive) which the item offers to the y-axis input flow of alternating current.BHDX
Y-axis Input Impedance Rating:
1.0 megohms
MRC:
An indication of the shape of the amplitude calibrating voltage waveform.BHDZ
Amplitude Calibrating Voltage Waveform:
Square wave
MRC:
The peak to peak value for which the item is calibrated.BHFB
Calibrating Peak To Peak Amplitude:
0.5 volts
MRC:
An indication of whether or not a calibrated screen scale is included.BHFF
Calibrated Screen Scale:
Included
MRC:
An indication of whether or not a trace storage tube is included.BHFH
Trace Storage Tube:
Included
MRC:
An indication of whether or not camera recording device accommodations are provided.BHFT
Camera Recording Device Accommodation:
Not provided