부품 번호 2224892

Electronic Chopper
묘사

Chopper

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 340.62 and 459.837 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
2224892
비무장화:
No
수명:
N/A
측정 단위:
1 EA
NIIN:
008973559
NSN
국가 주식 번호:
5945-00-897-3559 5945008973559
TXT
묘사:
Electronic Chopper
INC
INC
아이템 이름 코드:
19759
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
7
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Solder lug/stud
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 1.500 inches and 1.530 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
Between 0.745 inches and 0.763 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-65.0/+100.0 degrees celsius
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Single pole, double throw
MRC:
Indicates the type of unit.APQB
Unit Type:
Electromechanical
MRC:
An indication of whether or not a hermetically sealed feature is provided.AXNN
Hermetically Sealed Feature:
Provided
MRC:
An indication of whether the drive voltage is the same as,or different from,the input voltage.BGRB
Drive Voltage Relationship To Input Voltage:
Unequal
MRC:
The value,or range of values,for which the drive is rated.BGRC
Drive Voltage Rating:
6.3 ac pounds per hour wet
MRC:
The number of complete cyclic changes,per unit of time,for which the drive is rated.BGRG
Drive Frequency Rating:
400.0 hertz
MRC:
An indication of whether the item is designed to actuate /make/ a contact before or after the preceding contact deactuates /breaks/.BGRK
Contact Operation Sequence:
Breaks before makes
MRC:
The value,or range of values,for which the contact is rated.BGRL
Contact Voltage Rating:
100.0 ac pounds per hour wet
MRC:
The amount of current for which the contact is rated.BGRM
Contact Current Rating:
2.0 milliamperes
MRC:
The difference in phase between two alternating quantities having the same frequency,expressed in degrees.BGRN
Phase Angle In Deg:
30.0
MRC:
That portion of each driving cycle during which electrical continuity exists between the center contact and one stationary contact,expressed in degrees.BGRP
Dwell Time Rating In Deg:
Between 65.0 and 100.0
MRC:
An indication of whether or not a feature for plug in mounting is provided.BGRS
Plug In Mounting Feature:
Provided
MRC:
Indicates the connection location.BGRY
Connection Location:
Ac coil connection on opposite end

{lang[cimilar]} Electronic Choppers

« Relays and Solenoids {lang[catalog]}
지금 비교»
맑다 | 숨기다