부품 정보
Includes hp-1b interface and programmable input controls module; provides time period, pulse width, time interval and frequency measurement capabilities of automatic test system; operating conditions: temp 0 to 50 degrees c; 20-80 pct humidity; altitude sea level to 10, 000 ft
TXT
묘사:
Digital Reado Electronic Counter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
18.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
18.130 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac or dc
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 48.0 hertz and 66.0 hertz
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
2
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Bnc
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
Indicates the designed use of the item.ALXZ
Specific Usage Design:
Designed for agm-69a, cruise missile
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 100.0 volts and 240.0 volts
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
8
MRC:
The measured weight of an item unencumbered by packaging or packing material.AWJN
Unpackaged Unit Weight:
18.750 pounds
MRC:
The means of attaching the item.AXGY
Mounting Method:
Rack
MRC:
The name of the accessory component assigned by the controlling agency.AZCG
Accessory Component Name:
Power cord 229 cm; rack flange kit
MRC:
Indicates the type of measurement provided.BFHZ
Measurement Type:
Frequency and period average and ratio and time interval and totalizing
MRC:
The range of complete cyclic changes,per unit of time,for which the item is rated.BFJB
Frequency Range:
+0.000/+15.000 megahertz
MRC:
An indication of the deviation from a standard or true value for which the item is rated.BFJC
Accuracy Rating:
Porm 1 count porm time base error
MRC:
The interval of time during which the item provides a signal.BFJF
Gate Time:
Between 0.0001 seconds and 1.0000 seconds
MRC:
The rated sensitivity of the item.BFJG
Sensitivity Rating:
115 millivolts peak to peak
MRC:
An indication of whether or not an internal calibration feature is included.BFQM
Internal Calibration Feature:
Not included
MRC:
Indicates the type of display provided.BFQN
Display Type:
Led
MRC:
The number of digits displayed.BFQP
Display Digit Quantity:
8
MRC:
An indication of whether or not a display units indicator is included.BFQQ
Display Units Indicator:
Included
MRC:
An indication of whether or not a display positioned decimal point is provided.BFQR
Display Positioned Decimal Point:
Not provided
MRC:
An indication of whether or not a display storage facility is included.BFQS
Display Storage Facility:
Included
MRC:
An indication of whether or not provisions for remote control are included.BFQT
Remote Control Provisions:
Included
MRC:
An indication of whether or not a solid state feature is included.BFQW
Solid State Feature:
Included
MRC:
An indication of whether or not a provision for plug-in units is included.BFQZ
Plug-in Units Provision:
Not included
MRC:
An indication of whether or not a standard frequency/ies/ output feature is included.BFRB
Standard Frequency Output Feature:
Not included
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used to functionally test and fault isolate certain 5-52 electrical/electronic assemblies
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Differentiated by reparable parts