MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Hole mounted					
				 
							
					
						MRC:
						The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
					 
					
						Hazardous Locations/environmental Protection:
					
					
						Shock resistant and vibration resistant					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						1.250 inches 					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Length:
					
					
						0.500 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						1.000 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						1.250 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						0.875 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.114 inches 					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
					 
					
						Actuator Style:
					
					
						Round					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the actuator,and terminates at the circumference.AFUR
					 
					
						Actuator Diameter:
					
					
						0.250 inches 					
				 
							
					
					
						Actuator Height:
					
					
						0.125 inches 					
				 
							
					
					
						Actuator Free Position Height:
					
					
						0.563 inches 					
				 
							
					
						MRC:
						The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
					 
					
						Maximum Voltage Rating In Volts:
					
					
						250.0 ac and 28.0 dc					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Kurz and root co generator model 4					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Unthreaded hole					
				 
							
					
						MRC:
						The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
					 
					
						Nonpile-up Contact Arrangement:
					
					
						2 pole,  double throw,  double break/double make,  permanent jumper,  one position momentary single switch unit					
				 
							
					
						MRC:
						The amount to which the actuating force must be reduced to permit the switch to become unactuated.CRRM
					 
					
						Switch Release Force:
					
					
						4.0 ounces 					
				 
							
					
						MRC:
						The amount of force required to actuate the switch.CSJN
					 
					
						Switch Actuating Force:
					
					
						17.0 ounces 					
				 
							
					
						MRC:
						The movement of the switch actuator.CXQQ
					 
					
						Actuator Movement:
					
					
						Between 0.060 pretravel inches  and 0.015 overtravel inches and 0.028 differential inches 					
				 
							
					
						MRC:
						The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
					 
					
						Contact Load Current Rating At Maximum Rated Voltage:
					
					
						10.000 amperes resistive dc and 7.000 amperes inductive dc and 10.000 amperes resistive ac					
				 
							
					
						MRC:
						An indication of the precious material and its location in the item.PMLC
					 
					
						Precious Material And Location:
					
					
						Contacts silver					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						8 quick disconnect,  male