부품 정보
Nuclear hardened item
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
10.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
9.000 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Fungus proof
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Trans module station
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
15000.0 feet
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
103.5 ac pounds per hour dry single operating power rqmt and 129.0 ac pounds per hour with retaining chain single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
15.0 dc volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
17.0 dc volts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-5.0 dc volts 10th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
5.0 dc volts 6th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
5.0 dc volts 7th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
5.0 dc volts 8th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
5.0 dc volts 9th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
7.1 dc volts 3rd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
7.1 dc volts 4th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
7.1 dc volts 5th power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
380.0 hertz 1st alternate operating power rqmt and 420.0 hertz 1st alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.5 hertz 3rd alternate operating power rqmt and 52.5 hertz 3rd alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
57.0 hertz 2nd alternate operating power rqmt and 63.0 hertz 2nd alternate operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-10.0/+55.0 degrees celsius
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Over voltage protector and input to output isolation and input to case isolation and output to case isolation
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
1.9 dc amperes 2nd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.3 dc amperes 7th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.3 dc amperes 8th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.3 dc amperes 9th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
-0.1 dc amperes 10th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
3.7 dc amperes 1st power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
4.4 dc amperes 6th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
7.0 dc amperes 3rd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
7.0 dc amperes 4th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
7.0 dc amperes 5th power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
13 single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip single power output
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Terminal strip single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
2 single operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Convection
MRC:
The power supply operational efficiency when connected to an alternate current power line.CWWY
Power Supply Efficiency Line:
72.0