MRC:
						The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
					 
					
						Case Material:
					
					
						Plastic					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Nsn 2320-01-447-6345 chassis,  truck. W/s family of medium tachical vehicles					
				 
							
					
						MRC:
						The number of poles included in the item.AKPX
					 
					
						Pole Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						2 terminal					
				 
							
					
						MRC:
						The maximum current load that each pole is rated to carry continuously.CPLM
					 
					
						Maximum Continuous Load Current Rating Per Pole:
					
					
						15.0 amperes dc single location					
				 
							
					
						MRC:
						Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
					 
					
						Operating Voltage Type And Rating Per Pole In Volts:
					
					
						14.0 dc single location					
				 
							
					
						MRC:
						Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.CPRG
					 
					
						Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
					
					
						15.0 dc single location					
				 
							
					
						MRC:
						Indicates the type of electrical condition that will cause the device to trip.CPRH
					 
					
						Circuit Protection Type:
					
					
						Overcurrent single location					
				 
							
					
						MRC:
						Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
					 
					
						Special Features:
					
					
						Series 21x mini circuit breakers,  type 1,  14vdc					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						2 quick disconnect,  male