부품 정보
Hydraulics international - controller; chromalox - temperature and process controller
TXT
묘사:
Indicating Temperature Control
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-500.0/+5000.0 degrees fahrenheit
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
110.0 ac and 240.0 ac
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Test stand r/n 97386-102 cage 56529
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
0.2 and 0.1
MRC:
The minimum and maximum operating limits of the item.ASXT
Operating Range:
32 to +150 degrees f
MRC:
The source of power which drives the item.ATJK
Power Source:
External
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flush panel
MRC:
The maximum rated power that an item can safely consume or provide,measured in watts.AZQH
Maximum Wattage Rating In Watts:
120.0
MRC:
A maximum measurement of the longest dimension of an item,in distinction from width.CHQP
Maximumlength:
4.600 inches
MRC:
The maximum measurement taken at right angles to the length of an item,in distinction from thickness.CHQQ
Maximumwidth:
3.800 inches
MRC:
The maximum distance measured in a straight line from the bottom to the top of an item.CHQR
Maximumheight:
3.800 inches
MRC:
The intelligence data the item is capable of handling.CKQY
Intelligence Data Handling Capability:
Temperature receiving automatic
MRC:
The means provided to indicate data.CKQZ
Indication Method:
Receiving electrical digital display
MRC:
Indicates the type and location of the sensing element.CKRD
Sensing Element Type And Location:
Thermistor remote
MRC:
Indicates the type and location of the sensing element.CKRD
Sensing Element Type And Location:
Thermocouple remote
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Part number breakdown: 2104 - model number; r0 - relay/ jumper selectable ssr drive; 1 - dual relay form a contact; 4 - rs-422/485 digital communications, output numnber 5 and analog output; 0 - 110-240vacrdalghydraulics international dwg 97386-102 & chromalox commercial data
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 and 60.0
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Hydraulics international dwg 97386-102 & chromalox commercial data
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Vwill work with the following thermocouples - j, k, t, e, r, s, b; also will accept input signals of: 4-20ma, 0-5vdc, 1-5vdc; resistance thermometers 100 ohm pt rtd (alpha = 0.00385) and rtds (0.1 degrees res); set points - high & low