MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2a
MRC:
The minimum and maximum pitch diameter limits of a straight screw thread.AAJE
Thread Pitch Diameters:
Any acceptable
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Not rated
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.500 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.125 inches
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
1
MRC:
The longest distance between mounting centers parallel to the horizontal plane.AFDS
Longest Horizontal Distance Between Mounting Centers:
2.700 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-25.0/+105.0 degrees celsius
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-25.0 to 105.0 degrees celsius
MRC:
A measurement of the longest dimension of the stud,in distinction from width.AGXF
Stud Length:
0.250 inches
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
2
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Not rated
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Plastic
MRC:
The total oppositon (resistive and reactive) which the item offers to the input flow of alternating current.ANSL
Input Impedance Rating:
550.000 ohms
MRC:
The total opposition (resistive and reactive) which the item offers to the output flow of alternating current.ANSR
Output Impedance Rating:
550.000 ohms
MRC:
The differences between limiting frequencies of a frequency band.APQL
Frequency Bandwidth:
Not rated
MRC:
A measurement between specified points on a body in distinction from height.ARBR
Body Depth:
0.500 inches
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Threaded stud
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the mounting provision(s).BBBW
Mounting Provision Arrangement Style:
2 position in-line
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
3.000
MRC:
The means by which the signal is delayed.BZWM
Signal Delay Method:
Lumped constant
MRC:
The means used to vary the delay time of the item.CCDN
Delay Time Variation Method:
Tapped
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
2.000 microseconds single section
MRC:
The number of segments into which a section is divided.CCDR
Segment Quantity Per Section:
2 single section
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
1.805 microseconds single section 2nd segment err-100
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
195.000 nanoseconds single section 1st segment err-100
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
1.805 microseconds single section 2nd segment
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
195.000 nanoseconds single section 1st segment
MRC:
The change in delay as a result of the temperature change per degree celsius.CCDT
Delay Time Variation Per Deg Celsius:
Not rated
MRC:
The rated time required for the pulse to rise.CCDX
Pulse Rise Time Rating:
150.0 nanoseconds
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
5 wire leads
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.THDS
Thread Size And Series/type Designator:
0.112-40 unc
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Test central airborne weapon system, automatic