TXT
묘사:
Pulse Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.125 inches single group
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
100.00 microhenries single component single primary
MRC:
The average rate at which the pulses recur within a specified time interval.ACZN
Pulse Repetition Rate:
285.0 kilohertz all components
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.500 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
0.719 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
1.125 inches all mounting facilities all center groupings
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
2 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange single group and unthreaded hole single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 2 secondary single component
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 tab, solder lug