Power Switchboard
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
33.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
81.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
20.000 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Deck
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Navy standard g11 modified
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
For control and distribution of 120 v and 240 v, dc power from after 50 kw generator
MRC:
The name designation of the written or printed document.ALYQ
Document Title:
Components and accessories listed on buships dwg no. Lsd34-s6201-1531533 item b
MRC:
The element,compound,or mixture of which the panel is fabricated,excluding any surface treatment.ANJG
Panel Material:
Steel
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Dripproof
MRC:
The number of panels provided.APCA
Panel Quantity:
3
MRC:
The number of electrical inputs accommodated.APNW
Electrical Input Quantity:
1
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
120.0 dc volts
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
240.0 dc volts
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
120.0 dc volts 1st voltage rating
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
240.0 dc volts 2nd voltage rating
MRC:
An indication of whether or not an input neutral is provided.APNY
Input Neutral:
Provided
MRC:
The number of electrical outputs provided.APNZ
Electrical Output Quantity:
3
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
120.0 dc volts
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
240.0 dc volts
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
120.0 dc volts 1st voltage rating
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
240.0 dc volts 2nd voltage rating
MRC:
An indication of whether or not an output neutral is provided.APPC
Output Neutral:
Provided
MRC:
The amount of impact or shock an item is rated to withstand.APPD
Shock Absorbent Rating:
Navy hi shockproof
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Enamel
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Enameled