MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.016 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.094 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.641 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dustproof
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four 0.201 in. Diameter mtg holes spaced 2.125 in. C to c
MRC:
The basic structure of the item.ALXF
Structural Design:
Sectional
MRC:
The operating current for which the item is rated.APAM
Operating Current Rating:
55.0 milliamperes
MRC:
The value/s/ of direct current potential which must be applied to the item for operation,expressed in volts.APBR
Dc Operating Voltage Rating In Volts:
200.0
MRC:
Indicates the type of current used with the contact/s/.APFX
Contact Current Type:
Ac and dc
MRC:
The maximum voltage rating at which the contact is rated,expressed in volts.APLS
Contact Maximum Voltage Rating In Volts:
125.0
MRC:
The amount of current at maximum rated voltage for which the contact/s/ is designed.APLT
Contact Current Rating At Maximum Rated Voltage:
1.0 amperes resistive
MRC:
The maximum amount of current the contact/s/ will accommodate.APLW
Contact Maximum Rated Current:
10.0 amperes resistive
MRC:
An indication of the amount of voltage for which the contact/s/ is designed to withstand at the maximum rated current.APLX
Contact Voltage Rating At Maximum Rated Current:
115.0
MRC:
The specific number of contact terminals included.APNG
Contact Terminal Quantity:
12
MRC:
The specific number of coil terminals included.APNH
Coil Terminal Quantity:
2
MRC:
The specific number of common terminals included.APNJ
Common Terminal Quantity:
0
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Not provided
MRC:
The opposition that the coil offers to the flow of direct current.BDFT
Coil Dc Resistance:
3.6 kilohms
MRC:
The number of sections included.BWGP
Section Quantity:
1
MRC:
The number of coil winding(s) provided.CPWL
Coil Winding Quantity:
1
MRC:
An indication of the characteristic(s) of a winding.CPWM
Winding Characteristic:
Single wound untapped
MRC:
The measurement of the shaft rotation,expressed in degrees.CPWT
Shaft Rotation In Deg:
30.0