TXT
				
				
					묘사:
				
				
					Control Transformer Synchro				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						1.3093 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a flange,and terminates at the circumference.ABKK
					 
					
						Flange Diameter:
					
					
						0.9375 inches 					
				 
							
					
						MRC:
						The value of the primary excitation voltage for which the stator is rated,expressed in volts.AJSN
					 
					
						Stator Input Voltage Rating In Volts:
					
					
						11.8 					
				 
							
					
						MRC:
						The value of the primary excitation current for which the stator is rated,with rotor /secondary/ circuit open.AJSP
					 
					
						Stator Input Current Rating:
					
					
						16.0 milliamperes 					
				 
							
					
						MRC:
						The value of the primary /electrical/ excitation power for which the stator is rated.AJSQ
					 
					
						Stator Input Electrical Power Rating:
					
					
						0.5 milliwatts 					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.AJSS
					 
					
						Frequency In Hertz:
					
					
						400.0 					
				 
							
					
						MRC:
						Indicates the location of the terminal/s/ on the item.CQTM
					 
					
						Terminal Location:
					
					
						Rear					
				 
							
					
					
						Shaft Slot Depth:
					
					
						0.0250 inches  single shaft					
				 
							
					
					
						Shaft Slot Width:
					
					
						0.0265 inches  single shaft					
				 
							
					
						MRC:
						Indicates the type of shaft included on the item.CRSJ
					 
					
						Shaft Type:
					
					
						Round,  slotted single shaft					
				 
							
					
						MRC:
						The ratio of the output voltage to the input voltage at maximum coupling.CSJY
					 
					
						Transformation Ratio:
					
					
						1.100 rotor to stator 					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						5 wire lead