TXT
묘사:
Liquid Sight Indicator
MRC:
The industrial designation or term used to define the nominal diameter of pipe for which the item is designed.ACSU
Pipe Size For Which Designed:
0.500 inches both ends
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
13.500 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Poseidon
Sight Height:
12.000 inches
Sight Diameter:
0.625 inches
MRC:
The number of guard rods included.ASPM
Guard Rod Quantity:
2
MRC:
The length of a straight line which passes through the center of the tube for which designed,and terminates at the outside circumference.ASPP
Tube Outside Diameter For Which Designed:
0.625 inches both ends
MRC:
Indicates the type of end connection.AWZY
End Connection Type:
Threaded internal, swivel nut, flare both ends
MRC:
The maximum working pressure at which an item is designed to operate.BPHD
Maximum Working Pressure:
200.0 pounds per square inch
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Coupling nut
MRC:
Indicates the information designed to be visibly shown.CSQG
Furnished Data:
Liquid level
MRC:
The method or component used to visibly show the information required.CTCY
Data Furnishing Method:
Clear window
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Water
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Gage valve