부품 번호 196100

Otoscope And Ophthalmoscope Set

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 808.86 and 1091.961 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
196100
비무장화:
No
수명:
N/A
측정 단위:
1 SE
NIIN:
001656544

부품 정보
Otoscope & ophthalmoscope set oper btry pwr w/case

NSN
국가 주식 번호:
6515-00-165-6544 6515001656544
TXT
묘사:
Otoscope And Ophthalmoscope Set
INC
INC
아이템 이름 코드:
14867
MRC:
The number of lamps included with the item.AEWR
Lamp Quantity:
1
MRC:
The candlepower,or measurement of luminous intensity for which the lamp is rated,expressed in footcandles.AEWW
Err Default:
Err default
MRC:
The candlepower,or measurement of luminous intensity for which the lamp is rated,expressed in footcandles.AEWW
Lamp Candlepower Rating In Footcandles:
300.0
MRC:
The voltage for which the lamp is rated for normal operation,expressed in volts.AEWX
Lamp Voltage Rating In Volts:
2.5
MRC:
An indication of whether or not a container from which the item is completely removable in normal operable condition is provided.AFJU
Carrying Case:
Provided
MRC:
The number of lampholders included on the item.AHGF
Lampholder Quantity:
1
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Ophthalmoscope head lamp, 1; otoscope head lamp, 1
MRC:
The means used to operate the item.APHE
Operation Method:
Electrical
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
Battery
MRC:
Designates the size of the battery handle(s).CBTC
Err Default:
Err default
MRC:
Designates the size of the battery handle(s).CBTC
Battery Handle Size:
Medium
MRC:
The number of speculums provided with the item.CBTY
Speculum Quantity:
1 and 1 and 1 and 1 and 10
MRC:
The amount of current for which the lamp is rated.CBWC
Lamp Current Rating:
200.0 milliamperes
MRC:
Indicates the type of otoscope head provided.CMWP
Err Default:
Err default
MRC:
Indicates the type of otoscope head provided.CMWP
Otoscope Head Type:
Closed
MRC:
Indicates the type of speculum provided.CMWY
Speculum Type:
Aural and aural and aural and aural and optical
MRC:
The element,compound,or mixture of which the speculum is fabricated,excluding any surface treatment.CMWZ
Err Default:
Err default and err default and err default and err default and err default
MRC:
The element,compound,or mixture of which the speculum is fabricated,excluding any surface treatment.CMWZ
Speculum Material:
Plastic, thermoplastic and plastic, thermoplastic and plastic, thermoplastic and plastic, thermoplastic and plastic
MRC:
Designates the size of the speculum.CMXB
Err Default:
Err default and err default and err default and err default and err default
MRC:
Designates the size of the speculum.CMXB
Speculum Size:
2 millimeter and 3 millimeter and 4 millimeter and 5 millimeter and adult
MRC:
The designation derived from the name of the designer or the use for which the ophthalmoscope head is designed.CMXC
Err Default:
Err default
MRC:
The designation derived from the name of the designer or the use for which the ophthalmoscope head is designed.CMXC
Ophthalmoscope Head Design Designation:
May
MRC:
The number of lampholders included on the ophthalmoscope head.CMXD
Err Default:
Err default
MRC:
The number of lampholders included on the ophthalmoscope head.CMXD
Ophthalmoscope Head Lampholder Quantity:
1
MRC:
The number of lamps included with the ophthalmoscope head.CMXF
Err Default:
Err default
MRC:
The number of lamps included with the ophthalmoscope head.CMXF
Ophthalmoscope Head Lamp Quantity:
1
MRC:
The voltage for which the ophthalmoscope head lamp is rated,expressed in volts.CMXG
Err Default:
Err default
MRC:
The voltage for which the ophthalmoscope head lamp is rated,expressed in volts.CMXG
Ophthalmoscope Head Lamp Voltage Rating In Volts:
2.5
MRC:
The amount of current for which the ophthalmoscope head lamp is rated.CMXJ
Err Default:
Err default
MRC:
The amount of current for which the ophthalmoscope head lamp is rated.CMXJ
Ophthalmoscope Head Lamp Current Rating:
190.0 milliamperes
MRC:
The candlepower or measurement of luminous intensity for which the ophthalmoscope head lamp is rated,expressed in footcandles.CMXK
Err Default:
Err default
MRC:
The candlepower or measurement of luminous intensity for which the ophthalmoscope head lamp is rated,expressed in footcandles.CMXK
Ophthalmoscope Head Lamp Candlepower Rating In Footcandles:
3.5
MRC:
The negative range for which the ophthalmoscope head lens is rated,expressed in diopters.CMXS
Err Default:
Err default
MRC:
The negative range for which the ophthalmoscope head lens is rated,expressed in diopters.CMXS
Ophthalmoscope Head Lens Negative Range In Diopters:
-20.0/-1.0
MRC:
The positive range for which the ophthalmoscope head lens is rated,expressed in diopters.CMXT
Err Default:
Err default
MRC:
The positive range for which the ophthalmoscope head lens is rated,expressed in diopters.CMXT
Ophthalmoscope Head Lens Positive Range In Diopters:
+0.5 to 20.0
MRC:
An indication of whether or not a zero aperture is included on the ophthalmoscope head lens.CMXW
Err Default:
Err default
MRC:
An indication of whether or not a zero aperture is included on the ophthalmoscope head lens.CMXW
Ophthalmoscope Head Lens Zero Aperture:
Included
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Fiber optics; as differentiated by the furnished items and quantity requirements

{lang[cimilar]} Otoscope And Ophthalmoscope Sets

« Medical and Surgical Instruments, Equipment and Supplies {lang[catalog]}
  • 4303B
    NSN: 6515-00-166-7733
  • 2B8014
    NSN: 6515-00-166-7748
  • 5052/IPPB
    NSN: 6515-00-166-7758
  • 1222
    NSN: 6515-00-166-7760
  • 4775
    NSN: 6515-00-166-7771
지금 비교»