부품 정보
Contains front door, 26 inch dooropening; weight 425 lbs.; nema 12 ventilated; power rating 15kva at 0.8pflagging
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
35.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
30.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
18.000 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
F-15 aismf
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three 1st alternate operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three 2nd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
120.0 ac pounds per hour wet 1st alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
208.0 ac pounds per hour wet 2nd alternate operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
208.0 ac volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
120.0 ac volts 1st power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
60.0 hertz 1st alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
60.0 hertz 2nd alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
400.0 hertz 1st power output
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
400.0 hertz 2nd power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-40.0/+50.0 degrees celsius
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
42.0 ac amperes 1st power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
42.0 ac amperes 2nd power output
MRC:
The number of output alternating current phases.CWGN
Output Phase:
Three 1st power output
MRC:
The number of output alternating current phases.CWGN
Output Phase:
Three 2nd power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel 1st power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel 2nd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
1 1st power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
1 2nd power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Connector, receptacle 1st power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Connector, receptacle 2nd power output
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
39.0 ac amperes 1st alternate operating power rqmt
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
39.0 ac amperes 2nd alternate operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Convection and louvers