부품 정보
Circuit condition - nc-dry; uses stem assembly 192241, bottom of flange to activation level is 5 inches; drawing name - level switch (drain tank)
TXT
묘사:
Liquid Level Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
10.750 inches
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
24.0 volts
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
6.125 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Buoyancy
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Cable
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
20.0 amperes resistive load
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between -65.0 degrees fahrenheit and 250.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Vertical
MRC:
An indication of whether or not a relay is included.BJKG
Relay:
Included
MRC:
Indicates the type of liquid(s) for which the item is designed.BJKH
Liquid Type For Which Designed:
Hydraulic oil and lubricating oil and sea water and various fuels
MRC:
The mounting dimensions of the item.BJKP
Mounting Dimensions:
Six 0.562 in. Dia. Holes equally spaced on a 5.000 in. Dia. Bolt circle
MRC:
The relationship between the position of the float and the position of the contacts.CWTL
Float And Contact Positions:
Float down, contacts closed