측정 단위:
* special requirements. EA
TXT
묘사:
Electrical Plug Connector
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Hood, top opening w/clamp
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.125 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.250 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Vibration resistant
MRC:
The length of a straight line which passes through the center of the cable entrance,and terminates at the circumference.AFQJ
Cable Entrance Diameter:
0.625 inches
MRC:
The number of mating ends provided with the item which are designed to accommodate another connector.AFQW
Mating End Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the contact position/s/.AFQX
Contact Position Arrangement Style:
16 single mating end
MRC:
An indication of whether or not the contact(s) is removable.AFQZ
Contact Removability:
Nonremovable single mating end single contact grouping
MRC:
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
Contact Maximum Current Rating In Amps:
5.0 single mating end single contact grouping
MRC:
The maximum direct current potential that may be applied continuously to the contact without damage,expressed in volts.AFRE
Contact Maximum Dc Voltage Rating In Volts:
800.0 single mating end single contact grouping
MRC:
The means used to prevent mismating or cross plugging of contacts.AFRN
Polarization Method:
Fixed contact to contact
MRC:
Indicates the type of shell included on the item.AFRT
Shell Type:
Solid
MRC:
The means used to secure a connector to its mating counterpart.AFRV
Connector Locking Method:
Latch
MRC:
The means by which the connector cable is relieved of stress and strain.AFRW
Connector Cable Strain Relief Method:
Cable clamp
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Back single mating end single contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the contact is fabricated.CQTZ
Contact Material:
Copper alloy single mating end single contact grouping
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the contact surface(s) and cannot be wiped off.CQYH
Contact Surface Treatment:
Gold single mating end single contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the insert is fabricated.CQZG
Insert Material:
Plastic diallyl phthalate single mating end
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Tab, solder lug single mating end single contact grouping
MRC:
The chemical compound or mechanical mixture properties of which the shell is fabricated.CSPT
Shell Material:
Copper alloy
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the shell surface/s/ and cannot be wiped off.CSWM
Shell Surface Treatment:
Nickel
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
16 single mating end single contact grouping
MRC:
Indicates the type of contact(s) included with the item.CXCL
Included Contact Type:
Leaf spring single mating end single contact grouping
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
10001-1873771 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)