MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
1.000 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
1.722 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
1.000 inches
MRC:
The length of a straight line which passes through the center of the smallest cross section of a spline,and terminates at the circumference.AAUH
Spline Minor Diameter:
1.1050 inches single end
MRC:
The number of splines on or in the item.ABSA
Spline Quantity:
16 single end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
1.2450 inches single end
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac input
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
50000.0 feet
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Dustproof
MRC:
A measurement of the longest dimension of a spline,in distinction from width.AXFH
Spline Length:
0.2000 inches single end
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 unthreaded hole
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Ambient air
MRC:
The current rating of the control field,expressed in amperes.BFMJ
Control Field Current Rating In Amps:
0.060
MRC:
The impedance rating of the control field,expressed in ohms.BFMK
Control Field Impedance Rating In Ohms:
667.0
MRC:
Indicates the type of winding(s) of the control field.BFML
Control Field Winding Type:
Single winding w/center tap
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
No load
MRC:
Indicates the type of control field voltage and its rating,expressed in volts.BKPS
Control Field Voltage Type And Rating In Volts:
40.0 ac
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Horizontal mounting position
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.250 inches single end
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
-55.0 operating degrees celsius and 85.0 operating degrees celsius
MRC:
The length of a straight line which passes through the center of a mounting facility circle,and terminates at the circumference.CWFQ
Mounting Facility Circle Diameter:
0.875 inches
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
1500.0 single no load
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
0.265 single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A14 single style single end
MRC:
The number of alternating current phases.FAAZ
Phase:
Single input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
100.0 input
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead