부품 번호 170359

Electronic Control Amplifier

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 8717.8 and 11400.2 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
170359
비무장화:
Yes - DEMIL/MLI
수명:
N/A
측정 단위:
No qup EA
NIIN:
004378121
NSN
국가 주식 번호:
5996-00-437-8121 5996004378121
TXT
묘사:
Electronic Control Amplifier
INC
INC
아이템 이름 코드:
00096
INC
COM
컴플라이언스:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.562 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.938 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Vibration and shock resistant and moisture proof
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+5.0/+33.0
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+5.0 to 33.0
MRC:
The amplitude of vibration for which the vibration resistance frequency range applies.AFDN
Vibration Resistance Amplitude:
0.1 inches total excursion
MRC:
The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
Shock Resistance Rating In Gravitational Units:
50.0
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-28.0/+65.0 degrees celsius
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-28.0 to 65.0 degrees celsius
MRC:
The numeric value of the life expectancy of the item.AFHH
Average Life Rating:
25000.0
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Hours
MRC:
The numeric value indicating the average life expectancy for which the item is rated,expressed in hours.AFSV
Average Life Rating In Hours:
25000.0
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
Not rated
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Mechanical
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
400.0 hertz 2nd input channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
400.0 hertz 3rd input channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
400.0 hertz 1st input channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
400.0 hertz 1st input channel
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
400.0 hertz 2nd input channel
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
400.0 hertz 3rd input channel
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
Not rated
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
Not rated
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
100.000 volts input preset
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
26.000 volts interstage
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
100.000 volts output
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
26.000 volts input
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
74.0 volts
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
1.000 megohms input channel
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
Not rated
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
1st input channel synchro err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
1st output channel synchro err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2nd output channel synchro err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
3rd input channel synchro err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Tachometer
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
1st input channel synchro
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
1st output channel synchro
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2nd output channel synchro
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
3rd input channel synchro
MRC:
The maximum time an item will continuously run,expressed in hours.BJBM
Maximum Continuous Operating Time In Hours:
Not rated
MRC:
The length of time after impact that established the condition at which the shock resistance rating applies.BJBN
Shock Pulse Duration Time:
11.0 milliseconds
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Receptacle, power right side
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
400.0 single voltage
MRC:
Indicates the type and number of contact(s) included in the connection.BJBW
Connection Contact Type And Quantity:
6 receptacle, power internal and 12 receptacle, power internal
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
120.0 single voltage

{lang[cimilar]} Electronic Control Amplifiers

« Amplifiers {lang[catalog]}
지금 비교»
맑다 | 숨기다