부품 정보
Nipples drilled for safety wire
TXT
묘사:
Nonmetallic Hose Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
2.000 inches
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-40.0 degrees fahrenheit single response and 160.0 degrees fahrenheit single response
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-40.0 degrees fahrenheit and 160.0 degrees fahrenheit single response
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
Between 2.656 inches and 2.781 inches
MRC:
The specification or standard /industrial or governmental/ that specifically covers the construction of the hose or tubing,excluding the end fittings.ADLF
Hose Or Tubing Specification/std Data:
Mil-h-18288 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Self-sealing
MRC:
The minimum internal pressure rating,determined by destruction tests,at which the item can be expected to rupture.CQBD
Burst Test Pressure:
150.0 pounds per square inch
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
Outer layer molded rubber, chloroprene err-100
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
Outer layer molded rubber, chloroprene
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
45.0 pounds per square inch
MRC:
A steady,uniform,internal,static pressure that the item must withstand without leakage,abnormal distortion,or damage.CRDW
Hydrostatic Test Pressure:
75.0 pounds per square inch
MRC:
The type of protection provided by the outer covering.CRJM
Outer Covering Environmental Protection:
Abrasion resistant and mildew resistant
MRC:
The condition of the item with respect to the texture of the inner surface.CRWL
Inside Surface Condition:
Smooth
MRC:
The means used and the measurement of the longest dimension of an item.CRXX
Measuring Method And Length:
22.250 inches
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Inner conveying tube material-rubber, synthetic; nipples drilled for safety wire
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Fuel/oil, hydrocarbon single response
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
Mil-h-18288 professional/industrial association specification