TXT
				
				
					묘사:
				
				
					Electrical Fuse Link				
			 
			
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Slotted type					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Length:
					
					
						3.250 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
					 
					
						Mounting Slot Width:
					
					
						0.250 inches 					
				 
							
					
						MRC:
						The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
					 
					
						Case Material:
					
					
						Brass					
				 
							
					
						MRC:
						The maximum direct current,or root mean square current at rated frequency,that an item will carry continuously.AEBJ
					 
					
						Continuous Current Rating In Amps:
					
					
						120.000					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the terminal,in distinction from thickness.AFWW
					 
					
						Err Default:
					
					
						1.125 inches 					
				 
							
					
						MRC:
						The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
					 
					
						Maximum Voltage Rating In Volts:
					
					
						600.0 ac					
				 
							
					
						MRC:
						Indicates the type of over-current conditions that an item is designed to withstand indicated by the speed of circuit interruption.AFXF
					 
					
						Circuit Over-current Interruption Type:
					
					
						Time delay					
				 
							
					
						MRC:
						The means in which the item signals the interruption of a circuit.AFXH
					 
					
						Interruption Indicator Method:
					
					
						Opaque body					
				 
							
					
						MRC:
						The time elapsing before circuit interruption of an item operated at a specified percent of its normal current rating,expressed in seconds.CQPB
					 
					
						Circuit Over-current Interruption Delay Time In Seconds:
					
					
						10.0 400 pct of current rating