MRC:
						The basic material of which the body is fabricated.AAFZ
					 
					
						Body Material:
					
					
						Brass					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Angle give "adqm" or "adqn" if flanged one or two ends					
				 
							
					
						MRC:
						A narrative description of the type of end connection.ACKM
					 
					
						First End Connection Type:
					
					
						Threaded external tube					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
					 
					
						First End Style Designator:
					
					
						Flared					
				 
							
					
						MRC:
						The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
					 
					
						First End Thread Direction:
					
					
						Right-hand					
				 
							
					
						MRC:
						Indicates whether or not the second end is identical to the first end.ACLR
					 
					
						Second End Relationship With First End:
					
					
						Not identical					
				 
							
					
						MRC:
						A narrative description of the type of end connection.ACLS
					 
					
						Second End Connection Type:
					
					
						Threaded external tube					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
					 
					
						Second End Style Designator:
					
					
						Flared					
				 
							
					
						MRC:
						The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACMS
					 
					
						Second End Thread Direction:
					
					
						Right-hand					
				 
							
					
						MRC:
						The element,compound,or mixture of which the seating surfaces are fabricated.ACSH
					 
					
						Seat Material:
					
					
						Nickel copper alloy					
				 
							
					
						MRC:
						The angle of the end surface upon which the mated surface seats,expressed in degrees.ACTE
					 
					
						First End Seat Angle In Deg:
					
					
						37.0					
				 
							
					
						MRC:
						The angle of the end surface upon which the mated surface seats,expressed in degrees.ACTF
					 
					
						Second End Seat Angle In Deg:
					
					
						37.0					
				 
							
					
						MRC:
						The part that controls the flow through the item.ADQU
					 
					
						Flow Control Device:
					
					
						Poppet					
				 
							
					
						MRC:
						The number of end connections included in the item.ADQZ
					 
					
						End Connection Quantity:
					
					
						2					
				 
							
					
						MRC:
						A measurement of the longest dimension of a capillary tube.AEVT
					 
					
						Capillary Tube Length:
					
					
						60.000 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of a bulb.AEVU
					 
					
						Bulb Length:
					
					
						3.500 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
					 
					
						Bulb Diameter:
					
					
						0.500 inches 					
				 
							
					
						MRC:
						Indicates the type of control by which the valve is expanded.AFKK
					 
					
						Valve Expansion Control Type:
					
					
						Thermostatic					
				 
							
					
						MRC:
						Indicates whether the equalizer location is internal,external,or both.AFKU
					 
					
						Valve Equalizer Location:
					
					
						External					
				 
							
					
						MRC:
						Indicates the type of connection in the valve body for connecting the equalizer line.AFKV
					 
					
						Valve Equalizer Connection Type:
					
					
						Flared tube					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the valve equalizer connection,and terminates at the circumference.AFKW
					 
					
						Valve Equalizer Connection Diameter:
					
					
						0.250 inches 					
				 
							
					
						MRC:
						The capacity of the item as rated by industry,expressed in british thermal units /btu/ of refrigeration per hour.AGUB
					 
					
						Refrigeration Capacity In Btu Per Hour:
					
					
						36.0					
				 
							
					
						MRC:
						A designator distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.CQMM
					 
					
						First End Thread Series Designator:
					
					
						Unf					
				 
							
					
						MRC:
						The designation which is used for the purpose of general identification of the nominal thread size.CQYM
					 
					
						First End Thread Size:
					
					
						0.375 inches					
				 
							
					
						MRC:
						The designation which is used for the purpose of general identification of the nominal thread size.CRNB
					 
					
						Second End Thread Size:
					
					
						0.500 inches					
				 
							
					
						MRC:
						A designator distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.CRPF
					 
					
						Second End Thread Series Designator:
					
					
						Unf