MRC:
The different speeds at which the item may be operated.ABBB
Speed Adjustments:
Two speed
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.750 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
22.100 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
7.750 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
440.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Magnetic
MRC:
Indicates the performance capability of the item or component.AGLD
Performance Type:
Semiautomatic
MRC:
The number of fuses the item is designed to accommodate /including spares/.AGUE
Fuse Accommodation Quantity:
2
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Six 7/16 in. Diameter mtg holes on two rows of three holes each. Rows spaced 5-3/4 in. C to c, holes spaced 9-1/4 in. C to c
MRC:
An indication of the characteristic of the operating voltage.ANCN
Operating Voltage Characteristic:
Full
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
2.000
MRC:
The voltage required to actuate the item.ANDE
Actuator Voltage:
220.0 ac
MRC:
The value of current for which the fuse is rated,expressed in amperes.ANDG
Fuse Current Rating In Amps:
10.0
MRC:
Indicates the type of load for which the item is protected.ANDW
Load Protection Type:
Overload and undervoltage
MRC:
The temperature of the medium surrounding an item at which it can be operated.ANDX
Ambient Temp:
50.0 degrees celsius
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Dripproof
MRC:
An indication of whether or not the item is designed in conformance with the national electrical manufacturers association (nema) standards.ANQC
National Electrical Manufacturers Association Standards Design:
Not designed per nema std
MRC:
Indicates the type of control.AQZF
Control Type:
Remote
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Circuit protection fuse
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0