TXT
				
				
					묘사:
				
				
					Centrifugal Pump Unit				
			 
			
										
					
						MRC:
						The type of service with which the item is designed to be used.ACKL
					 
					
						Media For Which Designed:
					
					
						Sewage and water,  fresh					
				 
							
					
						MRC:
						The number of pumps incorporated in the item.AENC
					 
					
						Pump Quantity:
					
					
						1					
				 
							
					
						MRC:
						The maximum rated capacity delivered by the item.AHYV
					 
					
						Maximum Discharge Flow Rate:
					
					
						44.0 gallons per minute					
				 
							
					
						MRC:
						The sum of the total discharge head and the total suction lift.AHYX
					 
					
						Total Head:
					
					
						94.000 feet					
				 
							
					
						MRC:
						The vertical distance from the level of supply to the center of the pump.AHYY
					 
					
						Suction Lift:
					
					
						105.000 feet					
				 
							
					
						MRC:
						The speed of the item required to produce its rated capacity.AHYZ
					 
					
						Operating Speed At Rated Capacity:
					
					
						3450.0 revolutions per minute					
				 
							
					
						MRC:
						The position in which the pumping element/s/ is designed to operate.AHZA
					 
					
						Pumping Element Operating Position:
					
					
						Horizontal					
				 
							
					
						MRC:
						The number of impellers incorporated in the centrifugal pump.AHZF
					 
					
						Centrifugal Pump Impeller Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of prime mover included with the unit.AKDJ
					 
					
						Prime Mover Type:
					
					
						Electric motor					
				 
							
					
						MRC:
						The total electrical voltage.ELEC
					 
					
						Voltage In Volts:
					
					
						115.0