MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
7.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
12.000 inches
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Manual
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Rack
MRC:
Indicates the type of control.AQZF
Control Type:
Local
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
10.0 hertz operating channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
50.0 megahertz operating channel err-100
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
75.0 watts output
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms operating channel
MRC:
The length of time it takes the pulse to rise per channel.BHTQ
Pulse Rise Time Per Channel:
3.000 milliseconds operating channel err-100
MRC:
The length of time it takes the pulse to rise per channel.BHTQ
Pulse Rise Time Per Channel:
6.000 nanoseconds operating channel err-100
MRC:
The length of time it takes the trailing edge of the pulse to fall per channel.BHTR
Pulse Decay Time Per Channel:
10.000 milliseconds operating channel err-100
MRC:
The length of time it takes the trailing edge of the pulse to fall per channel.BHTR
Pulse Decay Time Per Channel:
10.000 nanoseconds operating channel err-100
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
10.000 volts operating channel err-100
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
33.000 millivolts operating channel err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Input channel pulse
MRC:
The physical configuration of the output wave.BJBJ
Output Wave Shape:
Pulse, trigger
MRC:
The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
Functional Classification:
Bb-1.1
MRC:
Indicates the date the item was entered into mil-hdbk-300.NTRD
Entry Date:
91-02-19
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
An/ard18 system