TXT
				
				
					묘사:
				
				
					Electrical Frequency Meter				
			 
			
										
					
						MRC:
						The type of electrical circuit in which the item is designed to be used.AACT
					 
					
						Circuit Current For Which Designed:
					
					
						Ac					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						2.420 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						4.180 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						4.730 inches 					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						60.0 hertz 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the mounting stud,in distinction from width.ADAG
					 
					
						Mounting Stud Length:
					
					
						0.500 inches 					
				 
							
					
						MRC:
						The distance between mounting facility centers.AEJN
					 
					
						Distance Between Mounting Facility Centers:
					
					
						5.3561 inches 					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Panel					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the arrangement of the mounting.ANRL
					 
					
						Mounting Arrangement Style:
					
					
						Two hole/stud					
				 
							
					
						MRC:
						The hue or tint of the dial scale marking(s).APMM
					 
					
						Dial Scale Marking Color:
					
					
						Black single indicator single range					
				 
							
					
						MRC:
						An indication of the accuracy of an item,expressed in percent.APPN
					 
					
						Accuracy In Percent:
					
					
						-3.0/+3.0 at full scale single indicator single range					
				 
							
					
						MRC:
						A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
					 
					
						Meter Depth Behind Mounting Flange:
					
					
						1.200 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the meter body behind the mounting flange, and terminates at the circumference.APSW
					 
					
						Meter Body Diameter Behind Mounting Flange:
					
					
						2.700 inches 					
				 
							
					
						MRC:
						The hue or tint of the background.AQFY
					 
					
						Background Color:
					
					
						White single indicator single range					
				 
							
					
						MRC:
						The source of power which provides the energy required for the operation of the item.AWZJ
					 
					
						Power Source:
					
					
						External					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						2 threaded stud					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+55.0/+65.0 hertz single indicator single range					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a mounting stud,and terminates at the circumference.BLKZ
					 
					
						Mounting Stud Diameter:
					
					
						0.112 inches 					
				 
							
					
						MRC:
						The means provided for selecting a scale.BLSB
					 
					
						Scale Selection Method:
					
					
						Terminal					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Zero adjuster					
				 
							
					
						MRC:
						The means employed to suspend the movement of the item.CTQL
					 
					
						Movement Suspension Method:
					
					
						Jewel pivot base					
				 
							
					
						MRC:
						The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
					 
					
						Circuit Attachment Method And Quantity:
					
					
						2 threaded stud					
				 
							
					
						MRC:
						The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
					 
					
						Operating Voltage Rating In Volts:
					
					
						120.0 ac 					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Plastic					
				 
							
					
						MRC:
						An indication of the nuclear hardness criticality of the item.NHCF
					 
					
						Nuclear Hardness Critical Feature:
					
					
						Nonhardened					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Rectangular flush mtg