부품 정보
Electromagnet in base provides pulsation of circulator plate in jar
TXT
묘사:
Constant Temperature Bath
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
12.000 inches
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base mounted
MRC:
A measurement of the longest inside dimension of an item,in distinction from width.ADJU
Inside Length:
12.000 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+30.0/+100.0 degrees celsius
MRC:
An indication of whether or not an insulated feature is included.AHGR
Insulated Feature:
Not included
MRC:
Indicates the type of heating element current whether alternating,direct,or both.BBJZ
Heating Element Current Type:
Ac
MRC:
The number of alternating current phases for which the heating element is designed.BBKB
Heating Element Phase:
Single
MRC:
A measurement of the capacity of an item.BBLT
Capacity Rating:
4.500 gallons
MRC:
The rated power the heating element can safely consume or provide,measured in watts.BBTG
Heating Element Wattage In Watts:
600.0
MRC:
Indicates the type of heating element provided.BDXJ
Heating Element Type:
Electric immersion
MRC:
The number of heating elements provided on the item.BKGK
Heating Element Quantity:
1
MRC:
The voltage value for which the heating element is rated.BKGR
Heating Element Voltage Rating:
120.0 volts
MRC:
The element,compound,or mixture of which the reservoir is fabricated,excluding any surface treatment.BNDF
Reservoir Material:
Glass, borosilicate
MRC:
An indication of whether or not the reservoir is removable.BNDG
Reservoir Removability:
Removable
MRC:
An indication of whether or not a constant water level attachment is included.BNDH
Constant Water Level Attachment:
Not included
MRC:
An indication of whether or not a low water cutoff is included.BNDJ
Low Water Cutoff:
Not included
MRC:
The hue or tint of the inner surface of the item.BNDK
Inner Surface Color:
Colorless
MRC:
An indication of whether or not a test tube rack is included.BNDM
Test Tube Rack:
Not included
MRC:
The number of complete cyclic changes,per unit of time,for which the heating element is rated.BNDP
Heating Element Frequency Rating:
50.0 hertz or 60.0 hertz
MRC:
An indication of whether or not an agitator is included.BNDQ
Agitator:
Not included
MRC:
An indication of whether or not a thermoregulator is included.BNDR
Thermoregulator:
Not included
MRC:
The range of accuracy for which the item is designed.BNDS
Accuracy Range:
-0.1/+0.1 degrees celsius
MRC:
An indication of the temperature regulating settings of the item.BNDT
Tempurature Regulating Settings:
Two variable pre-settings w/ring calibration dial
MRC:
An indication of whether or not cooling coils for below room temperature use are included.BNDW
Cooling Coils For Below Room Tempurature Use:
Not included
MRC:
An indication of whether or not a thermometer opening is provided.BNDX
Thermometer Opening:
Not provided
MRC:
An indication of whether or not a pilot light is included.BNDY
Pilot Light:
Included
MRC:
The physical configuration of the item.SHPE
Shape:
Cylindrical