TXT
묘사:
Fluid Pressure Regulating Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Brass
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight thru
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Air and hydraulic fluid, mil-h-5606
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Unthreaded internal tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Socket w/brazing ring
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACLH
First End Outside Diameter Tube Accommodated:
0.375 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The element,compound,or mixture of which the seating surfaces are fabricated.ACSH
Seat Material:
Plastic, polychlorotrifluoroethylene and steel, corrosion resisting
MRC:
The element,compound,or mixture of which the packing is fabricated.ADQT
Packing Material:
Plastic, polytetrafluoroethylene
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Steel, ams 5643
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The minimum to maximum limits of outlet pressure of the item.AEVA
Outlet Pressure Range:
+125.0/+275.0 pounds per square inch
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Automatic single stage
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Spring
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
3000.0 pounds per square inch