부품 번호 13-620-90

Ph Electrode

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 834.74 and 1126.899 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
13-620-90
비무장화:
No
수명:
12 mo.
측정 단위:
1 EA
NIIN:
010155980

부품 정보
For use in routine ph and titration measurements in aqueous and nonaqueous samples

NSN
국가 주식 번호:
6630-01-015-5980 6630010155980
TXT
묘사:
Ph Electrode
INC
INC
아이템 이름 코드:
42791
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
10.0 millimeters
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
140.0 millimeters
MRC:
A measurement of the longest dimension of an electrical lead,in distinction from width.AWCH
Electrical Lead Length:
30.000 inches
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Integral preconditioning solution vial and shielded
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Glass
MRC:
Indicates the type of instrument that the item will be used with,as suggested by either government specification or manufacturer.CYHA
Instrument Type For Which Designed:
No instrument designation
MRC:
The name of the item,other than a functional or application name,that industry has assigned.CYHC
Industry Designated Name:
General purpose combination
MRC:
An indication of the ph minimum and maximum testing/measuring limits of the item.CYHD
Ph Measurement Range:
+0.00/+14.00
MRC:
The minus and/or plus degrees of temperature the item can withstand without giving erroneous assay data.CYHE
Operating Temperature Range:
5.0 degrees celsius minus and 80.0 degrees celsius plus
MRC:
Indicates the type of junction employed in the item,to prevent unwanted ion interference.CYHG
Err Default:
Err default
MRC:
Indicates the type of internal electrode element employed to read a specific ion concentration in a sample/specimen or solution.CYHH
Internal Reference Element Type:
Silver/silver chloride
MRC:
Indicates the type of electrical lead connector included with the item.CYHJ
Err Default:
Err default
MRC:
Indicates the type and concentration of a solution needed to activate the item.CYHK
Err Default:
Err default

{lang[cimilar]} Ph Electrodes

« Chemical Analysis Instruments {lang[catalog]}
지금 비교»
맑다 | 숨기다