MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b single pressure connection
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Watertight
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.812 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.750 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.374 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
2.500 inches
MRC:
The general classification of a pressure switch based on the reference method used to measure the sensed pressure.AJZC
Pressure Switch Type:
Gage
MRC:
The means of attaching the item.AXGY
Mounting Method:
Bracket
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Automatic reset
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
18 single pressure connection
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
The maximum pressure that an item will withstand without resulting in any permanent changes in the structural,mechanical,or electrical characteristics.CQJB
Proof Pressure:
400.00 pounds per square inch
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.250 inches single pressure connection
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Two position in-line
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, double throw, one position momentary
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Connector, receptacle
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
15.0 amperes resistive load single voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Deactuation point adjustable and actuation point adjustable, preset
MRC:
The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
Contact Adjustment Range:
+0.20/+2.00 actuation point pounds per square inch gage and +0.15/+1.65 deactuation point pounds per square inch gage
MRC:
Indicates the type of device provided for manual adjustment of the contact(s).CTYS
Contact Adjustment Type:
Internal deactuation point hex nut and internal actuation point hex nut
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
480.0 ac at sea level single voltage
MRC:
Indicates the type of pressure connector.CTZL
Pressure Connector Type:
Swivel nut, compression, threaded internal single connection
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Npt single pressure connection