TXT
묘사:
Machine Tool At Grinding Machine
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
An indication of whether or not a container from which the item is completely removable in normal operable condition is provided.AFJU
Carrying Case:
Not provided
MRC:
The environmental elements or conditions that the motor is designed or protected to resist or withstand satisfactorily.AHZZ
Motor Environmental Protection:
Corrosion resistant or fungus resistant
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Grinder, cylinder
MRC:
Indicates the type of plug provided.ANTQ
Plug Type:
3-prong polarized
MRC:
Indicates the design type of the item.APGF
Design Type:
Precision tool post
MRC:
The rated horsepower of the electric motor.ASHK
Electric Motor Horsepower Rating:
10.00
MRC:
Indicates the type of mounting for which the item is designed.BCNX
Mounting Type For Which Designed:
Tool carriage
MRC:
The rated speed/s/ of the spindle,expressed in revolutions per minute.BMYR
Spindle Speed In Rpm:
Between 600.0 and 1400.0
MRC:
The maximum length of a straight line which passes through the center of the accommodation for the wheel,and terminates at the circumference.BMYS
Maximum Wheel Diameter Accommodated:
6.000 inches
MRC:
The maximum measurement of the smallest dimension of a wheel the item will accommodate,in distinction from length or width.BMYT
Maximum Wheel Thickness Accommodated:
6.000 inches
MRC:
An indication of the position of the feed.BQLN
Feed Position:
Horizontal
MRC:
Indicates the type of drive for turning,rotating,or positioning the wheel spindle mechanism.BQLP
Wheel Spindle Drive Type:
Direct
MRC:
Indicates the type of spindle provided.BQLR
Spindle Type:
Integral arbor
MRC:
The length of a straight line which passes through the center of an arbor,and terminates at the circumference.BQLT
Err Default:
Err default
MRC:
An indication of whether or not a motor radio interference suppression is included.BQMG
Err Default:
Err default
MRC:
An indication of whether or not an electric extension cable and plug is included.BQMK
Err Default:
Err default
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
220.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0