TXT
묘사:
Axial Pistons Pump
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Flange
MRC:
The number of cylinders incorporated in the item.AAXZ
Cylinder Quantity:
9
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Rectangular flange
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Rectangular flange
MRC:
Indicates the type of connection between the prime mover and the shaft.AAYX
Drive Connection Type:
Rigid coupled
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Hydrocarbon fuels and oils
MRC:
Indicates the type of pumping element included on the item.AENG
Pumping Element Type:
Piston
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Weapons code 97a, truck rubber ms deuce (dv100)
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
The direction in which the pump shaft turns during operation.AHZD
Pump Rotation Direction:
Counterclockwise
MRC:
The reciprocating design of the pump.AHZJ
Pump Reciprocating Design:
Single acting
MRC:
Indicates the type of reciprocating movement within the item.AHZN
Reciprocating Stroke Type:
Variable
MRC:
Indicates the type of device used to control the output or capacity of an item.AHZP
Volume Control Type:
Servo piston
MRC:
Indicates the location of the control on the item.AHZQ
Control Location:
Center
MRC:
Indicates the type of drive shaft by the physical configuration,condition,and the like of the shaft end.AJAB
Drive Shaft Type:
Tapered and threaded and woodruff keyway
MRC:
The length of a straight line which passes through the center of the drive shaft end,and terminates at the circumference.AJAC
Drive Shaft End Diameter:
1.000 inches