TXT
묘사:
Hydraulic System Bleeder Valve
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
160.0 degrees fahrenheit single response
MRC:
The minimum temperature at which the item is designed to operate.AEQJ
Minimum Operating Temp:
-25.0 degrees fahrenheit
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
5420-00-889-2020
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Hydraulic
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
3500.0 pounds per square inch single response
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Valve must be compatable with military - h - 46170, fluid temp range -25deg to 130deg, proof pressure = 5250psi, burst pressure = 8750psi, length = 4.27", width across flats = 2.00"
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Chromate
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like,that identifies the surface treatment material.STDC
Surface Treatment Specification:
Mil-std-171bronze or olive drab in color military standard all treatment responses