TXT
묘사:
System Pressure Regulating Valve
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Air
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Piston, free type
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
3
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Manual, double stage
MRC:
The means used to manually adjust the item.AEVP
Manual Control Method:
Knob
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Spring
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
4500.0 pounds per square inch
MRC:
The rated variance of the outlet pressure from the set pressure.AEWB
Outlet Pressure Accuracy Rating:
2200.000 pounds per square inch
MRC:
An indication of whether or not a filter is included.AEWF
Filter:
Not included
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
Between -0.0 degrees fahrenheit and 125.0 degrees fahrenheit