TXT
묘사:
Engine Coolant Radiator
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
34.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 24.930 inches and 25.070 inches
MRC:
An overall measurement of the smallest dimension of an item,in distinction from length or width.ADUM
Overall Thickness:
6.660 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
1450-00-930-8749; carrier guided msl m730
MRC:
A measurement taken at right angles to the length of the core,in distinction from thickness.AKMK
Core Width:
5.780 inches
MRC:
A measurement of the smallest dimension of the core,in distinction from length or width.AKML
Core Thickness:
0.009 inches
MRC:
The number of tanks provided.ALTH
Tank Quantity:
1
MRC:
A measurement from the bottom to the top of the core,in distinction from depth.ARPN
Core Height:
25.970 inches
MRC:
Indicates the type of outlet end connection.AWZX
Outlet End Connection Type:
Plain
MRC:
An indication of whether or not a filler neck is included.BJJQ
Filler Neck:
Included
MRC:
Indicates the location of the tank(s).BJKR
Tank Location:
Center
MRC:
The element,compound,or mixture of which the tank is fabricated,excluding any surface treatment.BJKS
Tank Material:
Brass
MRC:
A measurement from the bottom to the top of a tank,in distinction from depth.BJKT
Tank Height:
Between 34.500 inches and 34.750 inches
MRC:
A measurement taken at right angles to the length of the tank,in distinction from thickness.BJKW
Tank Width:
Between 24.660 inches and 24.790 inches
MRC:
A measurement of the smallest dimension of a tank,in distinction from length or width.BJKX
Tank Thickness:
5.880 inches
MRC:
The number of cores provided.BJKY
Core Quantity:
1
MRC:
The element,compound,or mixture of which the core is fabricated,and its location.BJSC
Core Material And Location:
Brass
MRC:
Indicates the type of core provided.BJSF
Core Type:
Ribbon cellular
MRC:
Indicates a narrative description of the type of inlet end connection.BJSG
Inlet Connection End Type:
Plain
MRC:
The number of inlet connection ends provided.BJSH
Inlet Connection End Quantity:
1
MRC:
The physical configuration of the inlet connection end/s/.BJSJ
Inlet Connection End Shape:
Oval
MRC:
The number of outlet connection ends provided.BJSK
Outlet Connection End Quantity:
1
MRC:
The physical configuration of the outlet connection end/s/.BJSL
Outlet Connection End Shape:
Oval
MRC:
The number of filler neck(s) provided.BJSM
Filler Neck Quantity:
1
MRC:
An indication of whether or not a valve casing is included.BJSN
Valve Casing:
Included
MRC:
The maximum pressure at which the valve casing is rated.BJSP
Valve Casing Maximum Pressure Rating:
18.0 pounds per square inch
MRC:
Indicates the location of the valve casing.BJSQ
Valve Casing Location:
Integral w/filler neck
MRC:
An indication of whether or not a coolant level elbow check valve is included.BJSR
Coolant Level Elbow Check Valve:
Included
MRC:
An indication of whether or not a fan shroud is included.BJSS
Fan Shroud:
Included
MRC:
An indication of whether or not a mounting feature/s/ is included.BJST
Mounting Feature:
Included
MRC:
The means of attaching the item and its location.BLYY
Mounting Method And Location:
Flange side
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
19207-12269450 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)