MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac and dc
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
3.125 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.250 inches
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Leads 2
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Dial w/pointer
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Bench
MRC:
The rated sensitivity of the item.ANTG
Sensitivity Rating:
50.0 microamperes
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black single indicator all ranges
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-1.5/+1.5 at full scale single indicator 7th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 10th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 11th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 12th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 1st range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 2nd range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 3rd range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 4th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 5th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 6th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 8th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 9th range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.5/+2.5 at full scale single indicator 13th range
MRC:
The hue or tint of the background.AQFY
Background Color:
White single indicator all ranges
MRC:
The hue or tint of the pointer.ASSS
Pointer Color:
Red single indicator all ranges
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
Internal
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 1st range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 2nd range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 3rd range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 4th range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 5th range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 6th range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 7th range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator 8th range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Nonlinear single indicator 10th range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Nonlinear single indicator 11th range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Nonlinear single indicator 12th range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Nonlinear single indicator 13th range
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Nonlinear single indicator 9th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1.0 volts single indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+10.0 amperes, dc single indicator 8th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+10.0 kilohms single indicator 13th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+10.0 volts single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1000.0 volts single indicator 6th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2.5 volts single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+6.0/+36.0 decibels above or below one milliwatt single indicator 11th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-20.0/+10.0 decibels above or below one milliwatt single indicator 9th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-8.0/+22.0 decibels above or below one milliwatt single indicator 10th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+50.0 microamperes, dc single indicator 7th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+50.0 volts single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+500.0 volts single indicator 5th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+20.0/+50.0 decibels above or below one milliwatt single indicator 12th range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Switch and terminal
MRC:
The means employed to suspend the movement of the item.CTQL
Movement Suspension Method:
Taut band
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
Probe, direct contact
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Portable
MRC:
The measured weight of the actual container(s) or supporting device(s) which is in direct contact with the item and its contents.SUWT
Unit Of Issue Weight:
3.50 pounds