부품 정보
Dwg title: cable assembly, 4/104w513 (reciever cabinet). Cable used is r/n 56232 1213913-202 w/over all jacket of thermoplastic elastomer. Wire, m16878/5bfe0 and terminal lug ms25036-148, is used to connect the shield e101 to connector p1 backshell. M16878/5bfe0 is used to jumper gnd to shield, and pins 8 & 3 in connector p-1. Foil shield tin coated copper drain wire is 24 awg 7/32. Not authorized for areospace applications.
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
12.000 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Next generation radar (nexrad)
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Unprocessed 1st end all conductors
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Connector receptacle 2nd end all conductors
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
4
MRC:
Indicates the type and number of accessory wires furnished with the item.AWTB
Accessory Wire Type And Quantity:
1 drain
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
7 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
24 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
32 all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
2 twisted pair
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
M24308/2-1 2nd end all conductors
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
81349 2nd end all conductors
MRC:
A measurement of the longest dimension of an individual conductor,in distinction from width.CXGW
Individual Conductor Length:
2.000 inches 1st end all conductors
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black 1st position primary insulation fourth conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black 1st position primary insulation second conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Red 1st position primary insulation first conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
White 1st position primary insulation third conductor
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum 2nd position shield foil cable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper 3rd position shield braid, metallic cable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic fluorinated ethylene propylene 1st position primary insulation all conductors
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin 3rd position shield braid, metallic cable
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin core conductor all conductors
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Internal angle connector and stripped