부품 정보
Min. Ambient temp.=-65.0 deg. F.; insulation resistance=500 megohms min.At 500 vdc coil ground; weight=1.0 lb.Max.; internal spring data: spring rate=32.0 lbs. Per in.; spring force at 0.250 in. Stroke=8.0 lbs. Min.; solid outside dia.=0.181 in. Max.; free inside dia.=0.109 in. Min.; solid height=1.000 in. Max.; wire dia.=0.026 in.; free height=1.750 in.; mounting holes cskto 0.268 in. Dia. By 90.0 deg.
TXT
묘사:
Electrical Solenoid
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.922 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.260 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.510 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
3.017 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.201 inches
MRC:
The identifying part number assigned to the electrical connector receptacle.AEEF
Connector Manufacturer Part Number:
Pt02a-14-5p
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
165.0 degrees fahrenheit
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of magnetic coils provided.APAF
Magnetic Coil Quantity:
1
MRC:
A measurement of the opposition to the flow of direct or alternating current.APCC
Electrical Resistance:
2.17 ohms
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Intermittent
MRC:
The voltage rating at which the item is designed to operate,expressed in volts.ASXH
Voltage Rating In Volts:
Between 25.0 dc and 31.0 dc
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 unthreaded hole
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
W/spring
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.CBME
Cubic Measure:
12.6307 cubic inches
MRC:
The movement of the actuator when force is applied.CNXT
Actuator Stroke Type:
Pull
MRC:
The amount of linear force delivered.CNXW
Linear Force Delivered:
4.00 pounds
MRC:
Indicates the type of means provided for connection of the power takeoff.CNXX
Power Takeoff Connection Type:
Internal plunger
MRC:
The maximum linear travel from the de-energized to the energized position.CNYD
Energizing Stroke Maximum Length:
0.250 inches
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Two position in-line