TXT
묘사:
Radio Frequency Interfere Filter
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+10.0/+2000.0
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-62.0/+150.0 degrees celsius
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-62.0 to 150.0 degrees celsius
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms blank
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms blank
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
0.150 blank
MRC:
The greatest amount of voltage loss per function,resulting from the devices inherent opposition to the flow of electrical current.AHBE
Maximum Voltage Drop Per Function:
7.5 volts dc blank
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance blank
MRC:
The maximum permissible temperature increase in the item as a result of its operation under normal conditions.AHCG
Maximum Tempurature Rise:
25.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 wire lead input 1st function1 wire lead output 2nd function
MRC:
The maximum alternating current root mean square voltage that the insulating material/s/ of the item will withstand without resulting in disruptive discharge or deterioration.CQDZ
Maximum Dielectric Withstanding Ac Rms Voltage:
1000.0 volts at sea level
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
750.0 volts dc blank